WEET Can General Capacitors Be Used Instead of Safety Capacitors?
A safety X2 capacitor failure mode refers to a capacitor that, after failure, will not cause electric shock and harm the human body. For safety and EMC considerations, safety X2 capacitors application value are generally added to the power inlet.
It is a X2 capacitor that must be certified by national safety regulations and must be verified by testing service organizations, so safety capacitors in circuits cannot be replaced by general capacitors.
X capacitors are divided into X1, X2, and X3. Currently, the most commonly used capacitor is X2 safety capacitor,
WEET X2 capacitor value:
Operating Temperature: | -40°C~ +110°C |
Voltage Rating: | 310VAC |
Safety Approvals: | ENEC, VDE, UL,cUL.CQC |
Capacitance Range: | 0.0047 ~ 10.0μF |
Capacitance Tolerance: | std ±10% (K) |
Our company has four different Pitch Size specifications: P10mm, P15mm, P22.5mm, and P27.5mm. If you need, please contact us.